362 83 1MB
English Pages 16 Year 2005
Important
Installer Assembly Instructions Electrical Wiring Diagrams
Important Assembly Instructions Effective January 2005 Bulletin #542 (Replaces April 2003)
ELECTRICAL WIRING DIAGRAMS CONTROLS PAGE Reversing Drum Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Safety Disconnect Switch or Manual Start Switch . . . . . . . . . . . . . . . . . . . . . . . . . .4 Push Button Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Reversing Three Phase Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Non-Reversing Three Phase Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Reversing Single Phase Magnetic Starter (115 Volt) . . . . . . . . . . . . . . . . . . . . . . . .8 Reversing Single Phase Magnetic Starter (230 Volt) . . . . . . . . . . . . . . . . . . . . . . . .9 Non-Reversing Single Phase Magnetic Starter (115 Volt) . . . . . . . . . . . . . . . . . . .10 Non-Reversing Single Phase Magnetic Starter (230 Volt) . . . . . . . . . . . . . . . . . . .11
MOTOR Motor Wiring Diagram Single Phase 115/230 Volt . . . . . . . . . . . . . . . . . . . . . . . . .12 Motor Wiring Diagram Three Phase Single Voltage Motors . . . . . . . . . . . . . . . . .13 Motor Wiring Diagram Three Phase Dual Voltage Motors . . . . . . . . . . . . . . . . . . .13 Reliance Electric’s MD60 A-C Variable Speed Drive . . . . . . . . . . . . . . . . . . . . . . . . .14
●
Engineering Data
• Wiring Diagram — Reversing Drum Switch • Single Phase — Reversing Drum Switch — 115 Volts AC Input Power 115 Volt, Single Phase (L2) (L1) (GROUND)
1 2
3 4
5 6
To Motor (See wiring diagram Pg. 12) (T8) (T2 & T4) (T5) (T1 & T3) (GROUND)
To Change motor rotation, interchange T5 and T8 leads
The reversing drum switch is similar to the manual start switch, but has the added advantage of being able to reverse the motor. It is standard equipment on most HYTROL portable model conveyors, and is normally mounted near the conveyor drive. The reversing drum switch is considered as a single point control, but may be extended through the use of a remote control rod (optional item), allowing the operator to control the conveyor from either end. NOTE: This switch does not provide for motor overload protection.
• Single Phase — Reversing Drum Switch — 230 Volts AC Input Power 1 2
(L2) (L1) (GROUND)
(T1)
3 4
To Motor Wire nut together T2,T3, and T8 (See wiring diagram Pg. 12)
(T4) 5 6
(T5) (GROUND)
To Change motor rotation, interchange T5 and T8 leads
1. Customer is to ground switch and motor at points shown on diagram. 2. Consult national electrical code for wire size to be used for connections between motor and switch. 3. This method provides no overload protection for motor. 4. Hytrol Part No. 032.103 5. Allen-Bradley Reversing Drum Switch
• Three Phase — Reversing Drum Switch — 208-230/460 Volts AC Input Power (L1) (L3)
To Motor 1 2
3 4
(L2) (GROUND)
FWD
OFF
REV
5 6
(See wiring diagram Pg. 13)
(T1) (T3) (T2) (GROUND)
NOTE: To Change motor rotation, interchange any two line leads.
Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
3
January—2005
Engineering Data
●
• Wiring Diagram — Safety Disconnect Switch or Manual Start Switch The manual start switch is a simple “ON-OFF” switch that directly controls the motor power. It is suitable for a large number of conveyor applications not requiring a reversible operation. The manual start switch is a single point control and is normally mounted at or near the drive. NOTE: This switch does not provide: motor overload protection.
• Single Phase—115/230 Volts AC
(L2)
LINE
LOAD
1. In NEMA 1 Enclosure 2. Hytrol Part Number 032.1014 3. This Switch has no motor protection 4. Max. 30 Amps, 600 Volts 5. UL Listed 724F, CSA
(T2)
POWER
TO MOTOR SEE PAGE 12 LINE
LOAD
(L1)
(GROUND)
(T1) LINE
LOAD
(GROUND)
• Three Phase—208 - 230/460 Volts AC
(L3)
LINE
LOAD
(T3)
POWER
TO MOTOR SEE PAGE 13 (L2)
(T2) LINE
LOAD (T1)
(L1)
(GROUND)
Page:
4
January—2005
1. In NEMA 1 Enclosure 2. Hytrol Part Number 032.1014 3. This Switch has no motor protection 4. Max. 30 Amps, 600 Volts 5. UL Listed 724F, CSA
LINE
LOAD
(GROUND)
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
●
Engineering Data
• Wiring Diagram — Push Button Station Remote push-button stations, designed for magnetic starters, are used to control the starter coils. Starters may be controlled by single or multiple push-button stations. Hytrol’s standard control voltage through the push-button station is 115 volt, single phase.
• Single “Fwd-Rev-Stop” Station
• Single “Start-Stop” Station
FWD
START
A REV
A B
B
STOP C
STOP
C
D
GROUND
GROUND
• Two “Fwd-Rev-Stop” Stations
• Two “Start-Stop” Stations
FWD
START
FWD
START
A
A STOP
REV
REV
B
B
STOP
STOP
C GROUND
C
STOP
D
GROUND
• Three or More “Start-Stop” Stations START
START
• Three or More “Fwd-Rev-Stop” Stations FWD
FWD
FWD
REV
REV
REV
START A
A STOP
STOP
STOP
B C
B STOP
STOP
C
STOP
GROUND
D
GROUND
Center Station is TYP. Wiring for Three or More Push-Button Stations
Center Station is TYP. Wiring for Three or More Push-Button Stations Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
5
January—2005
●
Engineering Data
• Wiring Diagram — Reversing Three Phase Starter The reversing magnetic starter directly controls the current to the motor by actually closing the required set of contacts to cause motor rotation in the desired direction (Forward/Reverse), and provides a remote means of conveyor directional control. Remote pushbutton stations, designed for magnetic starters, are used to control the starter coils. Starters may be controlled by single or multiple pushbutton stations. Magnetic starters also provide the added feature of overload protection for the motor.
Three Phase Power, voltage as required for the motor
Page:
6
January—2005
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
●
Engineering Data
• Wiring Diagram— Non-Reversing Three Phase Starter The non-reversing magnetic starter directly controls the current to the motor by actually (closing) the required set of contacts to cause motor rotation in one direction, and provides a remote means of conveyor control. Remote pushbutton stations, designed for magnetic starters, are used to control the starter coil. Starters may be controlled by single or multiple pushbutton stations. Magnetic starters also provide the added feature of overload protection for the motor.
Three Phase Power, voltage as required for the motor
Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
7
January—2005
●
Engineering Data
• Wiring Diagram — Reversing Single Phase Magnetic Starter The reversing magnetic starter directly controls the current to the motor by actually closing the required set of contacts to cause motor rotation in the desired direction (Forward/Reverse), and provides a remote means of conveyor directional control. Remote push-button stations, designed for magnetic starters, are used to control the starter coils. Starters may be controlled by single or multiple push-button stations. Magnetic starters also provide the added feature of overload protection for the motor.
115 Volt, Single Phase Power
Page:
8
January—2005
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
●
Engineering Data
• Wiring Diagram — Reversing Single Phase Magnetic Starter The reversing magnetic starter directly controls the current to the motor by actually closing the required set of contacts to cause motor rotation in the desired direction (Forward/Reverse), and provides a remote means of conveyor directional control. Remote push-button stations, designed for magnetic starters, are used to control the starter coils. Starters may be controlled by single or multiple push-button stations. Magnetic starters also provide the added feature of overload protection for the motor.
230 Volt, Single Phase Power
Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
9
January—2005
●
Engineering Data
• Wiring Diagram — Non-Reversing Single Phase Magnetic Starter The non-reversing magnetic starter directly controls the current to the motor by actually closing the required set of contacts to cause motor rotation in one direction, and provides a remote means of conveyor control. Remote pushbutton stations, designed for magnetic starters, are used to control the starter coil. Starters may be controlled by single or multiple push-button stations. Magnetic starters also provide the added feature of overload protection for the motor.
115 Volt, Single Phase Power
Page:
10
January—2005
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
●
Engineering Data
• Wiring Diagram — Non-Reversing Single Phase Magnetic Starter The non-reversing magnetic starter directly controls the current to the motor by actually closing the required set of contacts to cause motor rotation in one direction, and provides a remote means of conveyor control. Remote pushbutton stations, designed for magnetic starters, are used to control the starter coil. Starters may be controlled by single or multiple push-button stations. Magnetic starters also provide the added feature of overload protection for the motor.
230 Volt, Single Phase Power
Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
11
January—2005
●
Engineering Data
• Motor Wiring Diagram
Figure B
SINGLE PHASE, 115/230 VOLT
NOTES: 1. To reverse motor rotation interchange T5 and T8 leads 2. Wiring reference
230 VOLT
115 VOLT
Page:
12
January—2005
L1
L2
JOIN
T1
T4,T5
T2,T3 and T8
Clockwise rotation
T1
T4,T8
T2,T3 and T5
Counter clockwise rotation
T1,T3,T8
T2,T4,T5
Clockwise rotation
T1,T3,T5
T2,T4,T8
Counter clockwise rotation
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
●
Engineering Data
• Motor Wiring Diagram Figure A
Figure C
THREE PHASE, SINGLE VOLTAGE MOTORS
THREE PHASE, DUAL VOLTAGE MOTORS 200-208/400-416 VOLT OR 230/460 VOLT
NOTES: 1. Y-CONNECTED 2. To reverse motor rotation interchange any two power leads
NOTES: 1. Y-CONNECTED, DUAL VOLTAGE MOTOR 2. To reverse motor rotation interchange any two power leads 3. Wiring reference 4. Motors with leads T10, T11, T12; these three leads are to be connected together. L1
L2
L3
TIE TOGETHER
230 VOLT OR 200-208 VOLT
T1,T7
T2,T8
T3,T9
T4,T5 and T6
460 VOLT OR 400-416 VOLT
T1
T2
T3
(T4,T7) (T5,T8) (T6,T9)
Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
13
January—2005
●
Engineering Data
• Reliance Electric’s MD65 A-C Variable Speed Drive
Page:
14
January—2005
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
●
Engineering Data
• Reliance Electric’s MD65 A-C Variable Speed Drive
Page:
TECHNICAL MANUAL HYTROL CONVEYOR COMPANY, INC. JONESBORO, ARKANSAS
15
January—2005
HYTROL CONVEYOR COMPANY, INC. 2020 Hytrol Drive Jonesboro, Arkansas 72401 Phone: (870) 935-3700 EFFECTIVE JANUARY 2005 Printed by PINPOINT PRINTING 1/05