Australia Standard Inspection of buildings Part 1: Pre-purchase inspections Residential buildings AS 4349.1-2007

This Standard was prepared by the Standards Australia Committee BD-085, Inspection of Buildings, to supersede AS 4349.1—

225 90 21MB

English Pages [36]

Report DMCA / Copyright

DOWNLOAD PDF FILE

Table of contents :
CONTENTS
Page
FOREWORD ........................................................................................................... 5
SECTION 1 SCOPE AND GENERAL
1.1 SCOPE ........................................................................................................................ 6
1.2 LIMITATIONS OF STANDARD ............................................................................... 7
1.3 REFERENCED DOCUMENTS .................................................................................. 7
1.4 DEFINITIONS ............................................................................................................ 7
SECTION 2 INSPECTION AGREEMENT
2.1 GENERAL ............................................................................................................ 9
2.2 PURPOSE OF INSPECTION ...................................................................................... 9
2.3 SCOPE OF INSPECTION ........................................................................................... 9
SECTION 3 INSPECTION
3.1 GENERAL ................................................................................................................ 12
3.2 AREAS TO BE INSPECTED .................................................................................... 12
3.3 DEFECTS .................................................................................................................. 13
3 .4 INSPECTION RECORDS ......................................................................................... 14
SECTION 4 THE REPORT
4.1 GENERAL ................................................................................................................ 15
4.2 REPORT CONTENT ................................................................................................. 15
APPENDICES
A PRE-PURCHASE STRUCTURAL INSPECTION .................................................... 18
B STRATA AND COMPANY TITLE PROPERTY INSPECTION .............................. 19
C BUILDING ELEMENTS AND SERVICES TO BE INSPECTED ............................ 20
D EXCLUSION OF ITEMS FROM INSPECTION ...................................................... 25
E CRACKING OF BUILDING ELEMENTS ............................................................... 27
F TYPES AND EXAMPLES OF DEFECTS ................................................................ 29
Recommend Papers

Australia Standard Inspection of buildings Part 1: Pre-purchase inspections Residential buildings  AS 4349.1-2007

  • 0 0 0
  • Like this paper and download? You can publish your own PDF file online for free in a few minutes! Sign Up
File loading please wait...
Citation preview

AS 4349.1-2007



en .s,,. w .s,,. CD

.....

I

N 0 0

....

Australian Standard® Inspection of buildings "C :.c E e

C.



Part 1: Pre-purchase inspections­ Residential buildings

C C 0 rn :J

5 C 0

� .c ·c

en

'c a.,~ Cl

� .9

Cl)

>,

c

0

2l C CJ)

g ai rn :J

ni C 0



CJ) C.

ai ..... rn :J

cxi

0 0 C\I

.c CJ) LL

..... C") C 0

...

C.

E

.9

"C CJ) rn

2l

STAN ARD

Australia

AS 4349.1-2007

28

TABLE El CATEGORISATION OF CRACKING IN MASONRY Width limit

Damage category

Hairline cracks

�0.1 mm

0

Fine cracks that do not need repair

�1.0 mm

1

Cracks noticeable but easily filled Doors and windows stick slightly

�5.0 mm

2

>5.0 mm, �15.0 mm ( or a number of cracks 3.0 mm or more in one group)

3

>15.0 mm, �25 mm but also depends on number of cracks

4

Description of typical damage and required repair

Cracks can be repaired and possibly a small amount of wall will need to be replaced. Door and windows stick service pipes can fracture. Weather-tightness often impaired. Extensive repair work involving breaking out and replacing sections of walls, especially over doors and windows. Doorframes distort. Walls lean or bulge noticeably, some loss of bearing in beams. Service pipes disrupted.

© Standards Australia

www.standards.org. au